VFC system (Optimizers)

The Variable Feed Control System (Air Supply Optimization System*) is a rugged, aesthetically designed unit manufactured using instruments and components from internationally reputed manufacturers. All instruments conform to IP65 degree of protection for industrial applications. The design also ensures reliability and built in fail to safety feature. All units operate on control power supply of 230V AC and have an Intelligent Controller with precise online digital pressure display.

Our new range of SVD series VFC system is a result of thorough and in-depth field research of pneumatic applications. The system gives segregated dual pressure output to multiply the savings.

Available Models:


SVL Series:
A low pressure model suitable for low-pressure applications upto 3.5 Kg/cm2 and capacity upto 20,000 CFM.

SVM Series:
A medium pressure model suited for general industrial applications at pressures ranging from 3.5 to 10 Kg/cm2 and capacity upto 20,000 CFM.

SVH Series:
A high pressure model suited for high-pressure industrial applications above 10 Kg/cm2 and capacity upto 20,000 CFM.

SVD Series:
A state-of-the-art system which gives a dual pressure output ranging from 3 Kg/cm2 to 10 Kg/cm2

VFC System (Air Supply Optimization System*)

In conventional compressed air systems, the generating side is directly connected to the demand sector. While the generation of compressed air remains constant, the compressed air requirement in the plant keeps varying, due to which there is always heavy fluctuation of pressure. VFC optimizes and controls the flow of compressed air and makes the plant more energy efficient and ensures that quality and production is consistent. VFC tracks the demand for compressed air on real-time basis and meets the requirements of the air supply by variable feed. The VFC system is installed between the demand sector and the receiver. The optimum operating pressure is decided on the basis of audit findings and set in the system. The VFC isolates the demand sector from the generation side but maintains communication between the two and works in conjuction with each other thereby reducing compressed air consumption and leakages, which results in direct energy saving. 

Salient Features:

Up to 25% saving in energy

Tropicalised to Indian conditions

Stabilizes pneumatic systems

Dual set point

Pay back period 3-12 months.

Consistency in quality and lower rejections

Pressure output accuracy 0.01 Kg/cm2

Connectivity to PC

Fail to safety design

Dual pressure output on demand


* Patent Pending